China's high-quality production of Roots blower

Roots blower is a positive displacement blower, there are two trefoil relative rotation of the impeller and the casing wall by sealing the space, since each impeller is involute or epicycloidal package envelope impeller processing line, three blades of each impeller are exactly the same, while two impellers are also identical, thus greatly reducing the difficulty of processing. When impeller machining CNC equipment to ensure that the center distance of two impellers in the same situation next, no matter what position the two impellers to rotate, can maintain a certain minimum gap, to ensure gas leak within the allowable range.

Two impellers rotated in opposite directions, due to the clearance between the impeller and the impeller, the impeller and the casing, the impeller and the wall between the minimum, so that the air inlet is formed a vacuum, into the intake air chamber under the atmospheric pressure, and then, wherein each of the impeller blades and the two panels, the chassis constitutes a sealed chamber, an air intake chamber during rotation of the impeller, the blades are formed by two seal chambers constantly brought to the discharge chamber, and because row gas chamber impeller are engaged with each other, so that the air is squeezed out between the two blades, so that a continuous non-stop operation, the air from the intake port steady flow delivered to the outlet, which is the Roots blower the entire work process.

Folding property

As a result out of the inner form of clover rotor structure and reasonable housing outlet structure, so the fan vibration, low noise.

And the overall structure of the impeller shaft and impeller wear-free fan performance enduring, long-term continuous operation.

Fan capacity utilization, high volumetric efficiency, and compact structure, flexible installation.

Bearing selection is reasonable, uniform each bearing life, thus extending the life of the fan!

Fan made of imported fluorine rubber seal materials, high temperature, wear and long life.

Models range to meet the needs of different users for different purposes.

Folding operating conditions

1, the transmission medium inlet temperature is usually not greater than 40 ℃.

2, the content of the medium particles should not exceed 100mg / m3, the maximum particle size must not exceed half of the minimum working gap.

3, operation bearing temperature not higher than 95 ℃, oil temperature not higher than 65 ℃.

4, can not be higher than boost pressure range specified on the nameplate.

5, Roots blower impeller and the casing, the impeller and the side panels, the impeller and the impeller clearance factory adjusted to ensure that the gap when reassembled.

6, blower operation, the main fuel tank, fuel tank oil level in the oil level gauge must be between the two red lines.

7. Check whether the import and export joint portions forget sturdy place, the support pipe adequacy. Water used as a coolant blower, cooling water pump to check whether the installation meets the requirements.
http://www.lxrfan.com



2016年6月29日星期三

Used in the chemical characteristics of the centrifugal fan

1, with centrifugal fan blowing smoke dual function, one machine, you can use suction, you can also use a hair;
2, less oil or oil-free operation, the output of the air is clean;
3, with respect to the centrifugal fan and the air compressor, its pressure is much higher, often more than ten times the centrifugal fan;
4, if the pump is an integral casting, installation and use of the foot shock, the installed base of its requirements are very high pressure air GHBH
Low, even without fixed foot to normal operation, very convenient, but also very save installation costs and installation period;
5, relatively similar fan, its low noise operation, as refine high-pressure machine to launch ultra-quiet fan:
6, maintenance-free; it is only the loss of two pieces of bearings within the warranty period, with almost no maintenance;
7, high pressure aircentrifugal fan mechanical wear is very small, because in addition to bearing outside, no other mechanical contact portions, so of course, life is very long, as long as it is under normal conditions of use, 3 to 5 years is no problem of;
http://www.lxrfan.com/products_info/High-Pressure-ID-Fans-for-Smoke-or-Air-330145.html


2016年6月28日星期二

Characteristics of high pressure centrifugal fan

1, high pressure centrifugal fan with blowing smoke dual function, one machine, you can use suction, you can also use a hair;

2, less oil or oil-free operation, the output of the air is clean;

3, with respect to the centrifugal fan and the air compressor, its pressure is much higher, often more than ten times the centrifugal fan;

4, if the pump is an integral casting, installation and use of the foot shock, the installed base of its requirements is very low, even without fixed foot to normal operation, very convenient, but also very cost-saving installation and installation period;

5, relatively similar fan, its low noise operation, the introduction of high-pressure ultra-quiet fan:

6, maintenance-free; it is only the loss of two pieces of bearings within the warranty period, with almost no maintenance;

7, high pressure air mechanical wear is very small, because in addition to bearing outside, no other mechanical contact portions, so of course, life is very long, as long as it is under normal conditions of use, 3 to 5 years is no problem of;


http://www.lxrfan.com

2016年6月27日星期一

High-quality Chinese-made centrifugal fan

. After the air flow into the fan axial impeller along the main radial flow. Such a centrifugal fan according to the principle of action made products, including centrifugal fan, centrifugal blowers and centrifugal compressors. Centrifugal fan is a complex structure of the equipment, the main air inlet valve, impeller, motor, the outlet composition. In different states, the effect of centrifugal fan is not the same. Therefore, different operating conditions partly dissenting, centrifugal fan effect will be affected. The centrifugal fan debugging to the best condition, can start from several aspects. 1, centrifugal fans allow full pressure start or step-down power, it should be noted that the current full voltage starting is about 5-7 times the rated current, voltage starting torque is proportional to the square of the voltage, when there is insufficient network capacity, should step-down start. 2, centrifugal fan during commissioning, should carefully read the product manual, check the wiring method if the same wiring diagram is consistent; should carefully check the supply fan power supply operating voltage is not meet the requirements, whether the power phase or same phase, electrical components are assigned capacity to meet the requirements. 3, the number of test less than two, one to control power, fans observed a man running, and found anomalies immediately stop inspection; First check the direction of rotation is correct; after centrifugal fan starts running, you should immediately check the operating current of each phase is balanced the current exceeds the rated current; if not normal, you should stop to check. After running for five minutes, the fan down to check whether there are anomalies, confirming that no anomalies and then start running. 4, two-speed centrifugal fan test, it should start low, check the direction of rotation is correct; must be stationary when starting the fan speed and then start to prevent high-speed reverse rotation, causing damage to the motor and switch tripping. 5, when the centrifugal fan up to speed, the fan should be measured input current is normal, centrifugal fan operating current can not exceed the rated current. If the operating current exceeds the rated current, should check the supply voltage is normal. 6, centrifugal fan motor power required is defined as the condition of the centrifugal fan and wind chassis, the required high power inlet fully open. If the air inlet fully open operation performed, the risk of damage to the motor. When the fan is best to test the fan inlet or outlet valve on the pipeline closed, the operation will gradually open the valve, until the desired working conditions, and pay attention to the fan operating current exceeds the rated current. When installing wind cabinet, subject to the following requirements: 1. When used for fire, the exhaust port and smoke machines should be interlocked, when any one of the exhaust ports open, smoke machine that is able to automatically start 2 The fan installation ambient gas entrained sticky substances, dust and hard particle content should not be greater than 150mg / m3. When the fire smoke is not required 3. Install the fan should have a damping device, install ceiling should be securely fastened. 4. When use power outlet, the fan power cable should be connected with compliance with safety standards plug; when the fan power cable is connected directly to the power line; power supply line should be fitted with a contact separation of at least 3mm all-pole power switch. Distribution should be installed motor protection devices. 7.5Kw motor should have more power down and start-up device.

We are Henan cents Run Fan Manufacturing Co., Ltd. We are professional do the fan manufacturers.
http://www.lxrfan.com/products_info/High-Pressure-ID-Fans-for-Smoke-or-Air-330145.html


2016年6月26日星期日

Environmental newly designed centrifugal fan

Xianrun has developed high pressure blowers-in-series systems to achieve static pressure, previously unachievable by single stage centrifugal blowers.


Series and parallel connected blower installations are often used to meet performance ranges beyond normal single stage blower capacities. For systems that require high ststic pressure, and especially high pressure TOGETHER with high temperature (where standard multi stage, positive displacement, screw, or regenerative type blowers can not be used) series of single stage centrifugal blowers can be used. Many times additional blower in the system can be advantageous. For instance, where two blowers are operating in series and one breaks down, the other may be able to "limp" the system along while the necessary maintenance is performed. Having on blower continue in operation can often allow limited production while the other is being repaired. Also, there are cases where having one blower continue in operation could prevent or at least minimize system or equipment damage from such things as high temperature ot contaminated airstreams.

Another advantage of blowers in series is that of the availbale space. If system must be expanded and increaases the CFM requirements, the allotted space for the original blower may not be large enough for a single large blower, but might be large enough to istall two smaller blowers in series to obtain the necessary pressure.
One more potentail advatage for series operation is the likehood of initial cost savings. Although each case must be evaluated individually, it is often more economical to select two "smaller" blowers with their respectice smaller motors and drives than to select one "larger" blower to do the job.

Series connected blowers are those which have the outlet of the one blower exhausting into the inlet of another blower. By connecting blowersa in such a manner, high static pressures can be attained. This is accomplished as the second blower adds its pressure capability to the system, increasing the capacity beyond the capabilities of the first blower.

Ideally, two identical blowers installed in series would result in the same CFM at the outlet of the second blower as the inlet of the first one, and nearly twice the static pressure as that rated for either blower alone. However, some variation will result in both air flow and combined pressure because of the tendency of air to compress under pressure. A good understanding of how atnoshperic pressure and absolute temperature affect density is required. Both of these factors are involved in the proper selection of blowers. Density is directly proportional to atmospheric pressure and is inversely proportional to absolute temperature (degrees Rankine).
Caution is necessary in selecting blowers for series installtion. It is generally accepted that most pre-engineered blowers are capable of withstanding twice their catalog rated static pressure. In other words, where two blowers are installed in series the second blower housing should withstand the higher pressure. There is, however, a need for concern when the combined pressure exceeds twice the rated static pressure for one blower. In series applications involving three or more blowers, or in any system in which positive or negative pressure exists prior to the consideration of the blowers, special housing reinforcement may be necessary.
http://www.lxrfan.com/products_info/High-Pressure-Blowers-For-Smoke-Exhaust-330273.html



2016年6月24日星期五

Customer Fan Selection Method

In engineering or practical applications, a reasonable choice of fan is a very important job. Fan Once selected, it will run a number of years in the production and life, a reasonable selection will bring the user's convenience and efficiency. Fan selection principles are as follows.
1, before selecting fan, production and product quality should be aware of the market situation ventilators, such as ventilators produced varieties, specifications and a variety of special-purpose products, as well as departmental standards, national best products out of product, the new product development and promotion and so should take full account of environmental protection requirements in order to select the best fan.
2, depending on the fan conveying gas physical and chemical properties, select the fan for different purposes. Conveying explosive and flammable gas should be selected from the explosion-proof fan; row dust or transporting coal or pulverized coal should choose Dust fan; transport of corrosive gases should be chosen preservative fan; work in high temperature applications or conveying high temperature gas should be selected high temperature ventilators.
3, select the fan performance icon Richard have two or more fan when available, preference should be given a higher efficiency, smaller machine number, a large adjustment range, of course, should be compared, weighed pros and cons of a decision.
4, if the selected fan impeller diameter than the original fan impeller is too large a lot, in order to take advantage of the existing motor shaft, bearings and bearing, etc., must start time critical speed, strength and fan of the original components of the motor shaft etc. accounting.
5, the choice of centrifugal fan, when it is equipped with motor power less than or equal to 75kw, do not just start with the installation of the valve. When the carriage of high temperature flue gas or air and the choice of boiler centrifugal induced draft fan, which should be set up to use the valve to prevent operation when cold cause overload.
6, silencer required ventilation system should be first choice of high efficiency, low circumferential speed of the impeller fan, and make it work at maximum efficiency point; ventilation system should be based on modes of transmission of noise and vibration generated, take appropriate muffler and damping measures. Fan and motor damping measures, generally adopt damping base, such as a spring or shock absorber rubber shock absorbers.
7, the choice of fans, fans should avoid using parallel or series operation. When unavoidable, you should choose the same model, the performance of joint work with the ventilator. When used in series, the first stage should be a fan to a pipeline connection between the second stage fan.
8, the choice of new fans should consider the full use of existing equipment, suitable for on-site fabrication and installation and safe operation and other issues.
http://www.lxrfan.com/products_info/High-Temperature-Centrifugal-Fans-for-Cement-Plant-330150.html


2016年6月23日星期四

Axial Fans Description

Brief Description
Ordinary axial fan can be used for general factories, warehouses, offices, homes and other places within the ventilation, can also be used chillers (air cooler), an evaporator, a condenser, a spray-down, etc., are mine shaft flow fan,
Corrosion, explosion-proof axial fan using corrosion-proof materials and measures, and explosion-proof motor matching can be used to transport explosive, volatile, corrosive gases,
Gas delivery requirements axial fan should be no significant dust, non-sticky and fibrous substances; motor directly coupled to a temperature not exceeding 40 ℃, the belt drive type temperature does not exceed 60 ℃. The amount of conveying gas dust shall not exceed 150mg / m3,
Axial fan is mainly composed of the impeller, chassis, motor and other component parts, and the stent using steel casing duct connection. Wherein the anti-corrosion axial fan impeller, casing are made of glass and steel, other types of axial fans generally use steel.

Folding works
Energy when the impeller rotates, the gas from the air inlet axially into the impeller by the impeller blades push leaving the gas rises, and then flows into the vanes. Vanes will deflect the air flow into axial flow, while gas is introduced into the diffuser tube, further gas kinetic energy is converted to pressure energy, and finally to introduce the work of the pipeline.
Work axial fan blades and aircraft wings similar. However, the latter is to lift up the role on the wing and supports the weight of the aircraft, while the axial fan is fixed to the position and movement of air.
Cross-sectional axial fan generally airfoil. Blade position can be fixed, to be rotated about its longitudinal axis. Or blade pitch angle of the blades and airflow can be adjustable or non-adjustable. Changing the blade angle or pitch is one of the main advantages of axial fans. Small blade pitch angles produce lower flows while increasing the pitch may result in higher traffic.
Advanced axial fan blade pitch can be changed (which is quite similar to a helicopter rotor) during fan operation, thus changing the flow accordingly. This is called variable pitch (VP) axial fans.

Folding use
Axial fans called local fans, industrial and mining enterprises is commonly used as a fan, but it is different from the general fan motor and fan blade in a cylinder, the shape is a cylindrical shape, for local ventilation, easy installation, ventilation effect is obvious, safe, hairdryer lookout can be connected to the designated area.

2016年6月22日星期三

Application of high-capacity fan

The extensive media delivery model, a variety of sealing structure type, for the transfer of various gaseous medium, to meet different types of industrial uses. On the basis of the continuous improvement of the linear leaf absorbing international advanced design cycloid formed on the basis of technology and airfoil aerodynamic design of the theory. Aircraft design technology is mature. There are a variety of specifications, caliber 100 the following models left and right into the wind out of the wind, more than 100 models are motivated wind caliber side wind. Casting process and the choice of accessories to achieve a standard fluid machinery. Widely used in petroleum, chemical, metallurgy, electric power, fertilizer, building materials, minerals, ports, textile, food, medicine, environmental protection, farming and urban gas industrial enterprises.

Xianrun manufacture of various types of fans. Centrifugal blowers, axial fans. There are high-temperature, high pressure, wear and other fan. We can provide a full range of technical services, high-quality human services.

http://www.lxrfan.com/products_info/High-Capacity-Double-Suction-Fans-for-Power-Plant-330162.html



2016年6月21日星期二

Industrial Fan Maintenance

First, the maintenance of industrial fans
1 fan at no more than 40 ℃ ambient temperature long-term use, higher than 40 ℃, install exhaust fans and other cooling measures to improve fan life.
2, the fan motor itself to deal with each stop, the motor cooling impeller oil pollution clean-up dust, the motor can cool itself 2-4 ℃, so that the motor heat is good.
3, when the normal operation within 120-150 (5-6 days) additional hours of fan bearing grease once, and make records, to ensure that fuel in place, to ensure the normal oil tank gear.
4, the gap is small fan, a long time there will be stained with the normal operation of the air impeller sludge, leading to friction between the impeller is large, not only damage the impeller, noise, and will change the gap between the gears, so that the friction between the impeller greater. So when the air transport medium, the dust content should not exceed 100mg / m3, should be diligent replace the fan inlet filter cloth (based on the amount of wind changed weekly), clean room fan to ensure air purity of raw materials, and the other every six months on the fan impeller thoroughly cleaned once, and make records.

 Second, the industrial fan Caution
1, when the normal operation of the fan should be a comprehensive inspection of the components, parts are complete, each bolt and nut connection tightness, the installation of each fastener and locating pin is loose.
2, should stop and check each and find blower motor, alignment. Four weeks to check whether the base unit's entire pad is, the anchor bolts are tightened. Then run 20 minutes was observed to confirm.
3, regular replacement of gear oil to the oil tank to the oil grades prescribed injection bit lines being.
4, in order to ensure the normal continuous air feed supply, the normal production, the fan must be checked daily, to detect problems as soon as possible prepared to handle.

Third, the staff organization

1, blower bearings supplemented with additional butter from the production staff and make records.
2, the production inspection team found the problem device and check inspection records, and timely response to the situation up.
3, the fan check daily maintenance of the main subjects dealt with by the relevant technical personnel and make a record.

Fourth, safety precautions
1, unit vibration motor should be firmly grounded, should always check the tightening fasteners.
2, the fan is strictly prohibited overload, and increase or decrease the amount of wind should gradually slow operation.
3, between the motor and fan guard should be firmly installed, maintenance personnel should pay attention to check the person operating the motor bumps.
4, another implementation of the relevant provisions in accordance with Annex.

http://www.lxrfan.com/products_info/High-Quality-ID-Fan-for-Ventilation-330271.html


2016年6月20日星期一

Future trends fan

The fan industry has a long history, fans of national economic growth has made tremendous contributions. Fan products in the metallurgical, oil, petrochemical, refrigeration and other industries in various places and subway tunnels, marine and other countries has been widely used, mainly plays the role of ventilation. With the rapid growth of national economies, particularly efficient and environmentally friendly era, each state has increased infrastructure investment, and increased efforts to support the development of various industries, which is bound to stimulate the wind turbine market more prosperous. Chinese fan industry in the years of the development of continuous exploration, technology continues to improve, continuously enriched. So fan product development trend of the future is like?
First, to improve the efficiency of the fan is to adapt to the needs of a large industrial development trend
First, since the requirements of industrial production, the efficiency of the fan is the main direction of future development. Optimized turbine design structure, and strive to achieve the highest unit efficiency thereby expanding the adjustment range of the fan, so you can make the operating efficiency of the fan to get the maximum extent. This will be the fans companies need to increase research efforts to solve the problem.

Second, to reduce the volume of the fan, reduce the weight of the fan is to adapt to the trend of low-carbon environmental protection requirements
In improving the operational efficiency of the fan at the same time, reduce the volume of the fan, reduce the weight of the fan, so that products will get a broader market space. I believe that with the miniaturization of the latest technological achievements bearing industry applications, for fans of good design criteria.

Third, reduce the fan noise will run the fan favored by the market
Fan noise during operation generated by the equipment operator is a kind of labor damage, but in recent years, there is often a factory fan affect the normal life of the residents reported, so the future will be to reduce fan noise fan industry need to explore important subject.

Comprehensive future development trend of fan products, efficient, lightweight, low noise fan more products in the future market potential. Fan enterprises should grasp the development trend of the product at the same time, increase research investment, constantly optimize the design and performance of fan products, to the fierce competition in the market.




2016年6月19日星期日

Cement plant for large industrial fans

Cement production enterprises of the national economy in the production of energy guzzler, the cement industry has been listed as one of the key areas of resource conservation. Under the State Council to speed up construction of a conservation-oriented society policy environment, improve conservation-oriented manufacturing and application level cement industry, cement industry, the establishment of conservation-oriented system is significant. In the current domestic and international energy supply and demand contradiction, the cement manufacturers must reduce energy consumption through a variety of ways to get the best value for money and the highest labor productivity. In cement production, motor load power consumption accounted for nearly 30% of the cost, and drag the fan motor with a high-pressure account for a large proportion in the motor for a cement production line of which 25% to 30% of the electricity is used drag the various types of fans, so do the work of saving efficiency blower motor becomes extremely important.

At present, many cement plant fan big horse car phenomenon is serious, while air flow due to the conditions, changes in production, the system needs also change, most of the fans using the traditional approach that adjustment, the outlet valve opening degree implementation, and the method is to increase wind resistance, sacrifice efficiency of the fan to meet the requirements of a serious loss. If the use of frequency control technology to change the speed of the device to adjust the size of the wind, it can not only satisfy the production requirements, but also to achieve energy savings, while reducing wear and tear caused by the deflector baffles and pipes and downtime often caused by Economic losses. With the development of power electronics technology and electronic technology, variable frequency technology matures, the international fan for air volume, air pressure adjustment has generally been abandoned by adjusting the throttle opening means supporting, and replacing them with variable-speed electric drive adjustment, variable frequency adjustment speed has become the best choice for electrical transmission scheme fans, pumps and energy saving.

In the cement plant fan frequency control technology, significant energy savings can be improved, improve production efficiency, cement plants bring great economic and social benefits. Depending on the fan experience a large number of cement production line of energy-saving high frequency control, after using frequency control, electric fan consumption decreased by 8% to 45%, electricity to 0.50 yuan / kWh basis, usually recoverable inverter 1.5 to 3.5 years equipment installation and other additional expenses, etc. the total investment.

2, high-voltage inverter in cement production line fan energy-saving applications and benefits

Frequency control technology is now used in various industries, smart VFD from 2005 onwards energy-saving motors used in the cement industry, has been successfully used in six positions process cement production line of high pressure fans, namely: raw mill circulating fans, coal mill circulating fan, kiln exhaust fan, high temperature kiln fan, kiln exhaust fan, cement mill circulating fan, and has made many successful transformation experience, access to significant economic benefits .

After the table is to select different types of high pressure blower frequency conversion transformation instantiated data saving test results in a fully loaded system, the same environment, the requirement under the process conditions:

Type of fan motor power voltage level adjustment block Bankai opening degree operating power (kW) operating current (A) operating frequency frequency-converted before saving rate frequency inverter raw mill cycle 630KW 6KV throttle 80% 50,037,225 36.5% 64 43 coal mill cycle 560KW 10KV throttle% 80% 50,038,224 372 437 kiln exhaust damper 710KW 6KV 70% 58,236,936 39.9% 70 34.8 kiln exhaust 1000KW 10KV water resistance 80% 84,071,015 39.7% 61 42.9 High temperature 2500KW 10KV circulating fluid coupling 90% 26,002,350 9.6% 15,514,345 cement mill cycle 355KW 10KV throttle 45% 19,010,545 6.2% 17 36

Of particular note is required to control the pressure in the preheater kiln dry cement production process kiln temperature circulating fan, need to be adjusted for the amount of hot air circulating fan through the DCS control, the original design generally use hydraulic speed control coupler, wound rotor string resistance velocity modulation, etc., but the basic trend is currently developed rapidly in the 1990s and in recent years has proven technology and performance of high voltage AC variable speed technology is far better than before speed mode adopted, after a large number of successful field application and shows its great energy efficiency, high-voltage inverter is a national cement energy conservation design standard equipment. In our October 25, 2007 promulgated mandatory standards since May 1, 2008 implementation of the "GB50443-2007 cement energy-saving design specifications," the provisions of paragraph 4.3.5: "The high temperature kiln fan should adopt frequency modulation speed means. "

http://www.lxrfan.com/products_info/High-Quality-ID-Fan-for-Ventilation-330271.html

2016年6月17日星期五

High-performance anti-corrosion fan

Corrosion fan is to rely on the input of mechanical energy, increase the gas pressure of the gas feed side machine, which is a slave fluid machine, as compared with ordinary fans prevent corrosion. Is designed for the chemical and corrosion of ordinary steel have a greater input of toxic gas equipment design and manufacturing, to achieve the anti-corrosion fan ventilation in the same time, greatly extended service life.
Corrosion fan features:
 1, the fan inlet side must be installed set of wind, a hope that means protective wires.
 2, corrosion fan installation should pay attention to check the connection portion loose leaves and duct clearance should be uniform, not touching.
 3, connected to the outlet pipe weight should not be made with the fan duct, the installation should additional support.
4, anti-corrosion axial fan should be carefully checked before installation whether fans packing and shipping damage due to deformation, if damaged, to be repaired properly before proceeding to the installation, explosion shook his head fans, explosion-proof ceiling fans, explosion-proof exhaust fan wall fan shook his head, explosion-proof FRP axial fan
5, anti-corrosion axial fan fan base must naturally engage the ground plane can not be beat base mandatory connection to prevent deformation of the base, the school should be installed under the base, plus horn pieces, keeping the horizontal position, then tighten the ground.
 Corrosion fan widely used in factories, mine ventilation, tunnels, cooling towers, vehicles, ships and buildings, dust emission and cooling; boiler and industrial furnace ventilation and the wind; air-conditioning equipment and household appliances and cooling equipment ventilation; grain drying and sending; wind tunnel source and hovercraft inflation and propulsion.
http://www.lxrfan.com/products_info/High-Capacity-Double-Suction-Fans-for-Power-Plant-330162.html


China high quality industrial fan base - Xinxiang

Xinxiang, Henan provincial cities, located in the northern part of Henan Province, south of the Yellow River, near Zhengzhou, Henan Province, the provincial capital of the early days of the plain. Xinxiang Central Plains Economic Zone and the Central Plains Urban Agglomeration important core area of the city, but also the North of the economy, education, transport, trade and logistics center, the size of the city in Henan Province ranked third.
Xinxiang has China Excellent Tourism City, the industrial capital of Chinese fans, Chinese national "Transit City" model city, the National Intellectual Property Model City, National Sanitary City, National Garden City, National Forest City, the country's new energy vehicles to promote the city, China's most Jia commercial city, China the best ecological livable city and many other honors.
Company Introduction
Xinxiang Fan Main Factory Co.,Ltd. was established in 1985, mainly designs and manufactures Centrifugal fans,Axial flow fans and various fan components which are applied to industrial systems, which is the senior member of China General Xinxiang Industry Association.
Xinxiang Fan Main Factory Co.,Ltd.is one of the main large fan manufacturers in Central China, which owns more than 300 employees and the production capacity of 15000 sets one year.
There is an advanced Air Flow Test Laboratory in our company. We master mature fan designing, testing, manufacturing technology, and can design and manufacture multipurpose fans according to users' requirements. So, we are able to meet users' complex and professional applications. ZHONGSHENG BLOWER's products have been widely used in thousands of customers' industrial system, such as Coal-fired power, Metallurgy, Papermaking, Cement and Glass production, Chemical industry, Material handing, Sewage treatment, Waste incineration,Subway ventilation, Industrial boiler and Dust removal system etc.

Our Services 

1.We are a leading manufacturer of Centrifugal fans,Axial flow fans and various fan components.
2. We supply a wide range of products and provide one-stop service for Electronic Assembly Industry.
3. We keep a lot of stock for regular products and we can support small orders. Usually, our lead time is just 3 days.
4. We can also customize the products to fulfill different requirements.
5. Credibility: We are the 5th year Alibaba Gold Supplier. Our customers are located all over the world.  
6.Gratitude: We cherish and feel grateful to every customer for the business you give us. We are your reliable partner and will return to you with good products and good support.
7.Professional: We have been in this business for more than 10 years. We have a strong professional team with various experiences.
8. We keep doing new product development. Our goal is to enhance our competitive capacity constantly.
9. Price: we always offer competitive prices and help our customers to cost down.
10. Quality: we do 100% inspection before the shipment.
11. Promise: we are always ready to shoulder the responsibility if any loss caused to our customer due to our mistakes.
12. Warranty: 1 year warranty for all products.

http://www.lxrfan.comhttp://www.lxrfan.com

2016年6月16日星期四

Introduction of Xinxiang Fan Main Factory


Introduction of Xinxiang Fan Main Factory 

Our factory Xinxiang Fan Main Factory is established in 1985, and mainly designs and manufactures industrial fans and blowers, centrifugal fans,  industrial exhaust fan, air blower, axial fan, and various accessories. 

High Corrosive Blower Fan

With the factory covering an area of 100,000 square meters, we own 300 sets of production equipments and employ more than 150 managers and technical staff  members, as well as more than 350 professional and technical workers. We are the senior member of China General Machinery Industry Association (CGMA) and one of the largest blower manufacturer in central China with annual production capacity of 15,000 sets.
With an advanced air flow laboratory and mature blower design and manufacturing technology, we are able to design and manufacture multi-purpose blowers according to buyers' requests.



Xianrun Blower products have been widely used in thousands of customers' industrial system, such as coal-fired power, metallurgy, paper making, 
cement and glass production, chemical industry, material handing, sewage treatment, waste incineration,subway ventilation, industrial boiler and dust removal system etc.

Our products have been sold to many large industrial enterprises in China, and also sold to South America, the Middle East, Southeast Asia, and South Asia. We have got ISO9001:2008 quality management certification. Our products are of reliable performance and good quality and we are able to provide customers with competitive prices and timely delivery.


If you are interested in our products or services, please contact us. We look forward to establishing trade relationship with you.

2016年6月13日星期一

Custom Heavy Duty Industrial Fans and Blowers

Our factory specialize in industrial blowers and fans more than 30 years, our products include industrial blowers and fans, radial fans, industrial axial fans, centrifugal blowers and so on. We can also customize industrial blowers and fans according to your requirement. 


Air Temperature: 90~600
Impeller diameter:  1440~3211 mm
Pressure range:  1999~9786 Pa
Flow range:  39850~840000 cfm
Drive model: Coupling drive
Material: Cast Iron, Carbon Steel, Stainless Steel. 

Applications of custom heavy duty industry fans

(1) Industrial boiler, Garbage incinerator.Industrial waste heat recovery device.
(2) Cooling and heat dissipation
(3) Forced Ventilating: Generally used in ventilating for normal industrial and Large-scale buildings.
(4) Gas and materials transfer: General air delivery, Combustible gas delivery, Corrosive gas delivery, Gas mixed with impurity delivery.
(5) Eliminate dust and Particulate matter: Transfer the coal powder, Particle material, Powder material, Fragment materials, Fiber materials.

FAQ: 

Q1: What information do you need to provide in order to get a quotation?

A: Generally, information about Air Flow, Air Pressure, Air Temperature, Voltage and Frequency are needed in order to select a right fan for you and provide you a quotation.

Q2: What is the warranty of products?

A: All of our products have 1 year warranty. Every product has its own
production code. This code is able to track the production time.



Custom Heavy Duty Industry Fan

 Custom Heavy Duty Industry Fan
Performance of this custom heavy duty industry fan

Air Temperature: 90~600
Impeller diameter:  1440~3211 mm
Pressure range:  1999~9786 Pa
Flow range:  39850~840000 cfm
Drive model: Coupling drive
Material: Cast Iron, Carbon Steel, Stainless Steel. 

Applications of custom heavy duty industry fans: 

(1) Industrial boiler, Garbage incinerator.Industrial waste heat recovery device.
(2) Cooling and heat dissipation
(3) Forced Ventilating: Generally used in ventilating for normal industrial and Large-scale buildings.
(4) Gas and materials transfer: General air delivery, Combustible gas delivery, Corrosive gas delivery, Gas mixed with impurity delivery.
(5) Eliminate dust and Particulate matter: Transfer the coal powder, Particle material, Powder material, Fragment materials, Fiber materials.

FAQ: 

Q1: What information do you need to provide in order to get a quotation?

A: Generally, information about Air Flow, Air Pressure, Air Temperature, Voltage and Frequency are needed in order to select a right fan for you and provide you a quotation.

Q2: What is the warranty of products?

A: All of our products have 1 year warranty. Every product has its own
production code. This code is able to track the production time.